Grade 3 Titanium Yield Strength: Values, Density and Hardness

Grade 3 titanium is a commercially pure titanium grade (UNS R50550) that sits between Grade 2 and Grade 4 in the ASTM classification. Because it carries a higher oxygen content than Grade 2, it delivers roughly 30 percent more yield strength while keeping the ductility and corrosion resistance that make unalloyed titanium attractive in chemical, medical and marine service. This guide covers the annealed yield strength of Grade 3 titanium, the effect of cold working, its density and hardness limits, and the standards that govern supply.

What Is the Yield Strength of Grade 3 Titanium?

In the annealed condition, which is the state in which commercial purity titanium is normally supplied and used, Grade 3 titanium has a yield strength (0.2 percent offset) of 380-480 MPa (55,000-70,000 psi). ASTM B265, the specification for titanium and titanium alloy strip, sheet and plate, fixes a minimum yield strength of 380 MPa for annealed Grade 3 so that every conforming lot behaves predictably in a stressed or pressure-retaining application.

The same specification sets a minimum tensile strength of 450 MPa and a minimum elongation of 18 percent in 50 mm for annealed Grade 3. That combination is why designers treat it as the medium-strength commercial purity grade: clearly stronger than Grade 1 or Grade 2, yet still more formable and weldable than Grade 4.

Standard Product form Min. yield strength Min. tensile strength Min. elongation
ASTM B265 Strip, sheet, plate 380 MPa 450 MPa 18 %
ASTM B348 Bar, billet, forging stock 380 MPa 450 MPa 18 %
ASTM F67 Wrought implant stock 380 MPa 450 MPa 18 %
ISO 5832-1 Wrought implant stock 380 MPa 450 MPa 18 %

How Cold Working Changes the Yield Strength

Cold rolling, drawing or stretch forming raises the yield strength of Grade 3 titanium by approximately 10-20 percent through work hardening, taking typical values to roughly 420-550 MPa (up to about 80,000 psi). Ductility falls in step, so cold-worked stock is normally chosen where stiffness, spring behaviour or fatigue strength matters rather than where severe forming is still required. When further shaping is needed, a vacuum or inert-atmosphere anneal restores the equilibrium structure and returns the material close to its 380-480 MPa band.

Annealed strip and plate: 380-480 MPa yield, maximum formability.

Cold rolled 10-20 percent: roughly 420-550 MPa yield, moderate ductility.

Stress relief after forming: typically 1 hour at 540-650 °C in vacuum or high-purity argon.

Chemical Composition of Grade 3 Titanium

Grade 3 is unalloyed titanium; its strength comes from tightly controlled interstitial elements rather than from alloying additions. Typical maximum values by weight are:

Titanium: balance

Oxygen: 0.35 % max - the main strengthening element

Nitrogen: 0.05 % max

Carbon: 0.10 % max

Iron: 0.30 % max

Hydrogen: 0.015 % max

Because oxygen is the dominant strengthener, a supplier that holds oxygen at the low end of the range will produce material closer to 380 MPa, while mid-range oxygen produces values nearer 450-480 MPa. Buyers who need tight property windows should therefore state the intended oxygen target on the purchase order in addition to the ASTM chemistry limits.

Density and Physical Properties

Density is essentially the same across the commercial purity grades: 4.51 g/cm³ (0.163 lb/in³) at room temperature. That is about 60 percent of the 7.85 g/cm³ of carbon steel and 56 percent of the 8.96 g/cm³ of copper, which is the main reason Grade 3 is selected where weight reduction matters but full alloy strength is unnecessary.

Property Value
Density 4.51 g/cm³ (0.163 lb/in³)
Modulus of elasticity approx. 103 GPa (14.9 Msi)
Thermal conductivity at 20 °C approx. 21.9 W/m·K
Melting point approx. 1668 °C
Coefficient of thermal expansion approx. 8.6 µm/m·K (20-100 °C)

Hardness Range of Grade 3 Titanium

Hardness depends on the processing state and on the test method used, so a single figure is misleading. The ranges below reflect normal commercial product tested with standard loads.

Condition Brinell (3000 kg / 10 mm) Rockwell Vickers
Annealed 150-180 HB B80-B90 HRB 160-200 HV
Cold worked 20-30 % 180-220 HB B90-B95 HRB 200-240 HV

Even in the harder cold-worked state, Grade 3 remains machinable and weldable, which distinguishes it from higher-strength alloyed grades where preheat, post-weld heat treatment and dedicated tooling become mandatory.

Frequently Asked Questions

Q: What is the minimum yield strength of Grade 3 titanium?
380 MPa (55,000 psi) in the annealed condition, as specified in ASTM B265 for strip, sheet and plate and in ASTM B348 for bar and billet.

Q: Is Grade 3 titanium stronger than Grade 2?
Yes. Annealed Grade 2 has a minimum yield strength of about 275 MPa, while Grade 3 is specified at a 380 MPa minimum, so Grade 3 is roughly 30 to 40 percent stronger.

Q: What is the density of Grade 3 titanium?
4.51 g/cm³, or 0.163 lb/in³, which is about 60 percent of the density of steel and 56 percent of that of copper.

Q: Can the yield strength be increased by cold working?
Yes. Cold rolling or drawing typically lifts yield strength by 10-20 percent to about 420-550 MPa, with a corresponding loss of elongation.

Q: What hardness does Grade 3 titanium have?
Annealed material normally falls in the 150-180 HB, 160-200 HV or B80-B90 HRB range; cold-worked material is harder at roughly 180-220 HB.

Q: Which standards cover Grade 3 titanium?
ASTM B265 for plate, sheet and strip, ASTM B348 for bar and billet, ASTM F67 and ISO 5832-1 for wrought implant material.