Is Nickel Alloy C276 Magnetic?
Nickel Alloy C276, also designated UNS N10276, is a solution-annealed nickel-molybdenum-chromium alloy with a deliberate tungsten addition. In the standard annealed condition it is essentially non-magnetic at room temperature, and a permanent magnet shows only a negligible pull when it is brought close to the surface.
The reason is microstructural. Alloy C276 is austenitic and keeps a face-centred cubic lattice at room temperature. Ferromagnetism in steels originates from the body-centred cubic ferrite phase, and because C276 contains no ferrite it cannot build up the magnetic domains that make carbon steel and ferritic stainless steel respond strongly to a magnet. Relative permeability values for annealed C276 sit very close to unity, which is why the alloy is treated as a non-magnetic material in instrument building, medical equipment and electrical engineering.
Two practical qualifications matter. First, heavy cold work such as severe bending, swaging or cold drawing can introduce a small magnetic response, because deformation increases dislocation density and can form minor magnetic second phases. Second, an as-welded surface may show a slightly stronger magnetic pull than the parent plate. Both effects are small, and a solution-anneal heat treatment restores the material close to its original non-magnetic state.
Composition of Alloy C276 (UNS N10276)
| Element | Specified range, wt. % |
|---|---|
| Nickel (Ni) | Balance |
| Molybdenum (Mo) | 15.0 - 17.0 |
| Chromium (Cr) | 14.5 - 16.5 |
| Iron (Fe) | 4.0 - 7.0 |
| Tungsten (W) | 3.0 - 4.5 |
| Cobalt (Co) | 2.5 maximum |
| Manganese (Mn) | 1.0 maximum |
| Silicon (Si) | 0.08 maximum |
| Carbon (C) | 0.010 maximum |
| Phosphorus (P) and Sulfur (S) | 0.030 maximum each |
| Vanadium (V) | 0.35 maximum |
The very low carbon and silicon limits hold intermetallic precipitation to a minimum during welding, while molybdenum and tungsten together provide the pitting and crevice corrosion resistance that makes the grade suitable for chloride-bearing media.
Magnetic Behaviour Compared with Other Materials
| Material | Typical magnetic response at room temperature |
|---|---|
| Carbon steel | Strongly magnetic |
| Martensitic stainless steel (e.g. 410) | Magnetic |
| Austenitic stainless steel 304 or 316 | Essentially non-magnetic; slight response after heavy cold work |
| Nickel Alloy C276 (UNS N10276) | Non-magnetic in the annealed condition |
| Titanium Grade 5 (Ti-6Al-4V) | Non-magnetic |
A simple workshop check is informative: a strong magnet is attracted firmly to carbon steel, weakly to cold-worked 304 stainless steel, and hardly at all to an annealed C276 part. That test is qualitative only. Where an actual permeability figure is written into a specification, the value should be measured on the specific heat and product form being supplied rather than assumed from the alloy name.
Standards, Product Forms and Corrosion Performance
ASTM B575 / ASME SB575 - plate, sheet and strip of low-carbon nickel-molybdenum-chromium alloy
ASTM B574 / ASME SB574 - rod and bar
ASTM B622 / ASME SB622 - seamless pipe and tube
ASTM B619 / ASME SB619, ASTM B626 / ASME SB626 - welded pipe and tube
ISO 15156 / NACE MR0175 - qualification for oil and gas service containing hydrogen sulfide
C276 is supplied as hot-rolled or cold-rolled plate, bar, seamless and welded tube, sheet and strip, forged and machined components, all in the solution-annealed condition and normally accompanied by an EN 10204 type 3.1 inspection certificate. The combination of high molybdenum and chromium allows the alloy to work in oxidising, reducing and mixed-acid media, and the tungsten addition specifically inhibits pit initiation. Sulfuric acid, hydrochloric acid, phosphoric acid, wet chlorine, hypochlorite solutions and seawater are all routinely handled. C276 also resists chloride-induced stress corrosion cracking, which is the failure mode that limits austenitic stainless steels in hot chloride service.
Typical Industrial Applications
Chemical processing: reactors, columns, heat exchangers and piping exposed to mixed acids
Pollution control: flue gas desulfurisation scrubbers, dampers, stack liners and ducting
Power generation: equipment handling aggressive flue gas condensates
Offshore oil and gas: seawater piping, risers and sour-service components
Pharmaceutical and food processing: vessels, valves and pipework that must be both corrosion resistant and non-magnetic
Because the material is non-toxic and does not become magnetised in service, it is also used for equipment where magnetic interference would disturb instruments or product handling. Non-magnetic behaviour is a property of the annealed product; designers who need a guaranteed permeability limit should state that limit on the purchase order so that the mill can select and verify the correct heat treatment.
Frequently Asked Questions
Q: Is C276 alloy magnetic?
A: No. In the solution-annealed condition nickel alloy C276 is essentially non-magnetic, with relative permeability close to unity.
Q: Why is C276 non-magnetic while carbon steel is strongly magnetic?
A: C276 has a face-centred cubic austenitic structure with no ferrite phase. Ferromagnetism in steel comes from the ferrite phase, so the alloy has no magnetic domains to align.
Q: Can C276 become magnetic after machining or welding?
A: A small magnetic response can appear after heavy cold work or on some as-welded surfaces. Solution annealing normally removes it.
Q: Does its non-magnetic character affect corrosion resistance?
A: No. Magnetic behaviour and corrosion resistance are independent properties, and the corrosion performance of C276 depends on composition and heat treatment rather than on magnetism.
Q: What is the difference between C276 and C22?
A: Both are nickel-molybdenum-chromium alloys, but C22 (UNS N06022) is formulated with a lower iron and tungsten content for improved resistance to oxidising media, while C276 retains its tungsten addition for pitting resistance in reducing acids.
Q: Is C276 suitable for chloride-containing service?
A: Yes. The molybdenum, chromium and tungsten content gives good resistance to pitting and crevice corrosion and to chloride stress corrosion cracking in many industrial environments.